Construction

Automotive

Engineering

Resources

About Us

TECHNICAL SUPPORT:
EMAIL US:
FOLLOW US:

Profiled Sheet Systems

As pioneers of built of up roofing and cladding systems, the natural progression was to expand our offering to include a fully warranted high performance, versatile complete system solution – AshGrid™ Duotherm. The new system combines our tried and trusted AshGrid™ support system with high quality exterior roofing or cladding sheeting and all the required fixings and accessories.

Historically, Ash & Lacy have manufactured profiled sheet in various forms for over 25 years. We offer a 32/1000, 19/1000 and Sinusoidal profiles, with optional anti-condensation fleece.

With our innovative manufacturing capabilities combined with our technical support services, we are able to offer a range of materials and material finishes, backed by technical services including u-value calculations, setting out, material take offs and fully assessed firewall constructions – supported by a 25 year system warranty.

A vast range of specification requirements can be achieved using AshGrid™ Duotherm systems, including aesthetics, U-Values, acoustics, fire resistance and vapour control.

Rural & Industrial Design & Building Association

Applications

  • Built Up Roof and Wall systems (minimum roof pitch 4 degrees).
  • Asbestos Encapsulation.
  • Firewalls.
  • Pitched Roofing.
  • Sound Absorption and Acoustic Management.

Features

  • Sheet length capability of 1.2m to 11m.
  • 0.7mm walkable liner.
  • Lightweight building envelope construction.
  • Class 1 and Class 3 rooflights available ex-stock in standard lengths.
  • Liner testing based on ACR(M)001:2014 – Test for non-fragility of large element roofing assemblies.

 

Please note we can provide a take-off service, including all fixings, AshGrid™, insulation, rooflights, fillers and flashings.

Materials & Finishes

  • Plastisol coated Steel.
  • HPS200 Steel.
  • Prisma Steel.
  • Enamel Coated Steel.

 

Please note we can provide a take-off service, including all fixings, AshGrid™, insulation, rooflights, fillers and flashings.

Sheet Specifications

  • Liner – 32/1000 0.7mm gauge and 19/1000 0.4mm gauge.
  • Also Available in 0.7mm 32/1000 with a perforated finish for ventilation or to provide sound absorption characteristics, perforated in house.
  • Weather Sheet – 32/1000 both roof and wall profiles, with the option of swages also available.

 

Please note we can provide a take-off service, including all fixings, AshGrid™, insulation, rooflights, fillers and flashings.

U Value Requirements

W/m²K Roof Vertical Walls Horizontal Walls (BX48)
0.16 280 – –
0.18 240 – –
0.20 220 210 –
0.25 180 170 180
0.26 170 160 180
0.35 130 120 140

Wind Load Calculations

To guarantee the structural integrity of AshGrid™ Duotherm roofing and cladding systems, a wind load calculation is required to ensure the correct centres of our AshGrid™ Duotherm brackets are determined to withstand the loads.

Please click here to download a project checklist, which can be completed and submitted to us, together with project drawings, by clicking here.

To make an enquiry concerning your calculation requirements, please complete the form below:

Warranty

All Ash & Lacy roofing and walling systems carry a warranty, either for the products supplied directly, or from the supply chain partners.

The Ash & Lacy IntegrAL warranty gives total confidence in the materials and products supplied, with cov-erage up to 25 years.