As pioneers of built of up roofing and cladding systems, the natural progression was to expand our offering to include a fully warranted high performance, versatile complete system solution – AshGrid™ Duotherm. The new system combines our tried and trusted AshGrid™ support system with high quality exterior roofing or cladding sheeting and all the required fixings and accessories.
Historically, Ash & Lacy have manufactured profiled sheet in various forms for over 25 years. We offer a 32/1000, 19/1000 and Sinusoidal profiles, with optional anti-condensation fleece.
With our innovative manufacturing capabilities combined with our technical support services, we are able to offer a range of materials and material finishes, backed by technical services including u-value calculations, setting out, material take offs and fully assessed firewall constructions – supported by a 25 year system warranty.
A vast range of specification requirements can be achieved using AshGrid™ Duotherm systems, including aesthetics, U-Values, acoustics, fire resistance and vapour control.


Applications
- Built Up Roof and Wall systems (minimum roof pitch 4 degrees).
- Asbestos Encapsulation.
- Firewalls.
- Pitched Roofing.
- Sound Absorption and Acoustic Management.

Features
- Sheet length capability of 1.2m to 11m.
- 0.7mm walkable liner.
- Lightweight building envelope construction.
- Class 1 and Class 3 rooflights available ex-stock in standard lengths.
- Liner testing based on ACR(M)001:2014 – Test for non-fragility of large element roofing assemblies.
Please note we can provide a take-off service, including all fixings, AshGrid™, insulation, rooflights, fillers and flashings.

Materials & Finishes
- Plastisol coated Steel.
- HPS200 Steel.
- Prisma Steel.
- Enamel Coated Steel.
Please note we can provide a take-off service, including all fixings, AshGrid™, insulation, rooflights, fillers and flashings.
Sheet Specifications
- Liner – 32/1000 0.7mm gauge and 19/1000 0.4mm gauge.
- Also Available in 0.7mm 32/1000 with a perforated finish for ventilation or to provide sound absorption characteristics, perforated in house.
- Weather Sheet – 32/1000 both roof and wall profiles, with the option of swages also available.
Please note we can provide a take-off service, including all fixings, AshGrid™, insulation, rooflights, fillers and flashings.

U Value Requirements
| W/m²K | Roof | Vertical Walls | Horizontal Walls (BX48) |
| 0.16 | 280 | – | – |
| 0.18 | 240 | – | – |
| 0.20 | 220 | 210 | – |
| 0.25 | 180 | 170 | 180 |
| 0.26 | 170 | 160 | 180 |
| 0.35 | 130 | 120 | 140 |

Wind Load Calculations
To guarantee the structural integrity of AshGrid™ Duotherm roofing and cladding systems, a wind load calculation is required to ensure the correct centres of our AshGrid™ Duotherm brackets are determined to withstand the loads.
Please click here to download a project checklist, which can be completed and submitted to us, together with project drawings, by clicking here.
To make an enquiry concerning your calculation requirements, please complete the form below:

Warranty
All Ash & Lacy roofing and walling systems carry a warranty, either for the products supplied directly, or from the supply chain partners.
The Ash & Lacy IntegrAL warranty gives total confidence in the materials and products supplied, with cov-erage up to 25 years.