AshGrid™ was the first spacer system for built-up metal roofing and cladding developed for the building envelope market. AshGrid™ has maintained its market leading position since its launch through a continued programme of research and innovative development.
The installation is a simple three step method which saves time and costs for onsite construction. Our Safe-Loc™ bar and bracket ensures tight fitting and reliable bar connections which are essential to ensure the stability of all spacer systems during constructions.
Unlike some systems that rely on fixings to prevent the bars separating the enhanced AshGrid™ AG40 spigot design with its Safe-Loc™ security feature provides enhanced structural performance and reduces risks on site at the click of a tab.
Manufactured to the highest standards including BS EN ISO 9001:2008, all AshGrid™ components are produced to Ash & Lacy design and performance specifications following stringent quality control procedures. Offering a wide range of bracket height and an assessed firewall solution, AshGrid™ is available nationwide from strategically positioned manufacturing locations.

Introducing AB40+
Building on four decades of proven performance, AB40+ is another step forward in Ash & Lacy’s trusted AshGrid™ spacer system, engineered to make specification and installation simpler than ever.
Developed from the proven AB40 bracket design, AB40+ offers universal application for roof applications, vertical cladding and horizontal cladding. Increased loadbearing capacity makes it suitable for more demanding roof and wall constructions, reducing component count on onsite installation time whilst providing enhanced thermal performance compared to ABV and BX48.

Why Choose AB40+?
- Universal & Versatile – Suitable for roofing, walling, over-roofing and overcladding applications.
- Stronger & Wider Spans – Enhanced load capacity with spans of up to 1.2 m.
- Faster Installation – Fewer components and direct fixing options improve on-site efficiency.
- Thermally & Acoustically Efficient – Strong thermal and acoustic performance.
- Non-Combustible – Contains no combustible materials.
- Proven & Reliable – Over 40 years of industry use, with easy specification and product traceability.
- Sustainable & UK-Made – Manufactured using renewable energy and easy to recycle.
- Wide Compatibility – Suitable for a range of roofing and cladding sheet profiles.
You may also be interested in Fixings
You may also be interested in AshGrid™ DuoTherm for a complete built-up solution

- Built-Up Flat Roofing Systems
- Asbestos Encapsulation
- Firewalls – Available with Glass Wool or Stone Wool
- Built-Up Cladding Systems
- Pitched Roofing

Features
- Safe-Loc™ spigots – fast, secure & safe bar joints with no requirement for fixings
- Ensures maximum spigot efficiency is always achieved & maintained
- High performance brackets – deeper ribs for improved structural performance
- Full solar PV support
- No requirement for anti-sway brackets for AB40 brackets below 250 mm construction
- No requirement for anti-sway brackets for AB40+ brackets
- Extensive range of bracket heights from 60 mm to 420 mm
- Range of adjustable brackets from 100mm to 315mm
- Comprehensive range of roof & wall solutions
- UK industry standard – more 55 million metres installed over 15 years
- Technical back-up & nationwide distribution
- SCI Assessed for structural capability
- Strong, simple, cost-effective solutions – the contractor’s preferred choice
- New universal AB40+ bracket for superior performance, reduced component count, quicker on-site installation

AshGrid™ AG40 Bar
1.25mm thick high yield galvanised steel
Supplied in Lengths of 1m,2m & 3m
AshGrid™ AB40+ Bracket
1.8mm thick galvanised steel
Bracket Depths (mm) – 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340, 360, 380, 400 & 420
AshGrid™ AB40 Bracket
1.6mm thick galvanised steel
Supplied with a 3mm thick EPDM base thermal isolator pad
Bracket Depths (mm) – 60, 80, 85, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190, 200, 210, 220, 230, 240, 250 & 280
ABV Bracket
1.6mm Thick Galvanised Steel
Bracket Depths (mm) – 180-400 in 20mm increments
BX48 Bar
1.25mm thick high yield galvanised steel
Supplied in 6m Lengths
BX48 Brackets
2.0mm thick galvanised steel
Supplied with a 2mm thick EPDM base thermal isolator pad or 10mm Rockwool Pad (Firewall Systems)
Bracket Depths (mm) – 119, 139, 159, 179 & 199
TH40 Bar
1.25mm thick high yield galvanised steel
Supplied in 6m Lengths
TH40 Brackets
2.0mm thick galvanised steel
Bracket height – 135mm

U Value Requirements
| W/m²K | Roof | Vertical Walls | Horizontal Walls (BX48) |
| 0.16 | 280 | – | – |
| 0.18 | 240 | – | – |
| 0.20 | 220 | 210 | – |
| 0.25 | 180 | 170 | 180 |
| 0.26 | 170 | 160 | 180 |
| 0.35 | 130 | 120 | 140 |
For project specific U-values, explore our free AshGrid™/DuoTherm U-Value calculator tool
Wind Load Calculations
To guarantee the structural integrity of AshGrid™ roofing and cladding systems, a wind load calculation is required to ensure the correct centres of our AshGrid™ brackets are determined to withstand the loads.
Request Engineering Calculations
To make an enquiry concerning your calculation requirements, please complete the form below:

The AshGrid™ range of support systems are supported by our IntegrAL Warranty to give confidence in the materials and products supplied. For specific details please contact Ash & Lacy Technical.