AshGrid™ DuoTherm is the latest innovation from Ash & Lacy, combining our tried and trusted AshGrid™ spacer systems with non-combustible thermal insulation, a choice of our standing seam or profiled sheet coverings, solid and acoustic liner, and all the fixings and ancillaries required for a comprehensive systemised solution.
AshGrid™ DuoTherm provides a high-performance manufacturing capability to produce cover sheet lengths of up to 11.5m in a myriad of materials and finishes allowing you access to a high-performance complete system for roofing and walling that meets even the most ambitious project specifications.


- Built-Up Roofing Systems
- Asbestos Encapsulation
- Firewalls – Available with Glass Wool or Stone Wool to achieve 15 and 30 minutes insulation
- Built-Up Cladding Systems
- Pitched Roofing

Features
- Suitable for new build and refurbishment projects.
- Perforated and solid liners produced in 5 different profile options, also available with swages.
- Sheet length capability of 11.5m for profile sheet and 17m for standing seam.
- A range of bracket depths to accommodate up to 420mm insulation and U values as low as 0.11.
- UK manufactured according to ISO:9001 and ISO: 14001.
- GRP Rooflights available in matching profiles.
- Mobile site roll-forming available for longer, continuous standing seam profiles.
- SCI assessed.

Profiled Sheet
- Material – Pre-coated steel in 0.4mm 0.5mm and 0.7mm gauges.
- Anti-condensation fleece option for single skin applications.
- Colour Options – BS & RAL Colours and Metallics.
- Textures – Leathergrain, Smooth and Embossed.
Standing Seam
- Material – precoated aluminium & steel, copper and zinc.
- Colours – RAL colours, Alu Natur, Zinc Coat, Stone/Concrete effect.
- Textures – Smooth, Stucco Embossed, Brushed and Leathergrain.

Profiled Sheet
Pre-coated Steel 0.4mm 0.5mm and 0.7mm gauge.
Standing Seam
Pre-coated Steel, Pre-coated Aluminium, Copper and Zinc in 0.7mm and 0.9mm.

U Value Requirements
- Based upon 1.0m bracket centres.
- Based upon 0.040W/mK Insulation.
DuoTherm 100 (Roof)
- Weather Sheet: AL32/1000 – 0.7mm
- Liner Sheet: AL32/1000 – 0.7mm

DuoTherm 200 (Wall)
- Vertical Sheeting (AG40)
- Weather Sheet: AL32/1000 – 0.7mm
- Liner Sheet: AL19/1000 – 0.4mm

DuoTherm 300 (Wall)
- Horizontal Sheeting (BX48)
- Weather Sheet: AL32/1000 – 0.7mm
- Liner Sheet: AL19/1000 – 0.4mm
| W/m²K | Wall |
| 0.35 | 130 |
| 0.26 | 170 |
| 0.25 | 180 |
| 0.18 | 200 |
Wind Load Calculations
To guarantee the structural integrity of AshGrid™ DuoTherm roofing and cladding systems, a wind load calculation is required to ensure the correct centres of our AshGrid™ DuoTherm brackets are determined to withstand the loads.
Request Engineering Calculations
To make an enquiry concerning your calculation requirements, please complete the form below:

The AshGrid™ DuoTherm System is supported by our IntegrAL Warranties, which range from 25-40 years to give confidence in the materials and products supplied. For specific details please contact Ash & Lacy Technical.