Log in to your account



 
 
   

ASHGRIDTM
         

U-Values

The thermal performance of roof & wall constructions utilising Ashgrid has been calculated to take into account the effects of two and three dimensional heat flow by using computer software to model the Ashgrid system. The table below details the depth of brackets required to achieve the desired U-value.

U-Value Table

  U–value
W/m²K
U–value
W/m²K
WALLS (mm)
Vt. Cladding
(Bar &
bracket)
Hz. Cladding
(Vertical
top hats)
Rock Mineral Wool
l=0.040 W/mK
0.20
220
-
-
0.25
180
180
180
0.35
-
140
140
Glass Mineral Wool
l=0.044 W/mK
0.20
240
-
-
0.25
190
190
200
0.35
-
140
140

Notes
  • Glass mineral wool l = 0.044 W/mK from previously 0.040 W/mK
  • Rock mineral wool l = 0.040 W/mK from previously 0.037 W/mK
  • All values include for insulation thickness and bracket depth
  • Ashgrid brackets assumed to be at 1m centres
  • Purlin centres assumed to average out to 1.2m
  • Rail centres assumed to average out to 1.0m